Flue gas monitoring

Gas Analyzer

15

Reproducibility

≤ 3.3% relative to measuring range limit value

O 2 measurement

≤ 0.2% by vol.

Uncertainty of measurement

≤ 2% of the measuring range limit value

Process temperature Sample gas temperatur

≤ +1,300 °C

Input analyzer system:

≤ +200 °C

Process pressure

850 hPa to 1,100 hPa

Process gas humidity Ambient temperature Storage temperature Ambient pressure Ambient humidity

≤ 40% by vol. +5 °C to +40 °C –20 °C to +70 °C

850 hPa to 1,100 hPa

≤ 90% relative humidity; non-condensing

Ex-approvals

ATEX Ex II, IIC T3: Analyzer cabinet Ex II, IIC T3: Gas sampling unit Ex I, IIC T3: Sample gas line

Electrical safety Enclosure rating Analog outputs Analog inputs

CE

IP65

0/4 ... 22 mA, 500 Ω; number depends on system configuration 0/4 to 22 mA, 100 Ω; number depends on system configuration; electrically isolated 48 V AC, 0.5 A, 35 W / 48 V DC, 0.5 A, 24 W; number depends on system configuration; electrically isolated 3.9 V, 4.5 mA, 0.55 W; number depends on system configuration

Digital outputs

Digital inputs

 Type of fieldbus integration TCP

Modbus

RTU RS-485

 Note Option

PROFIBUS DP

PROFINET

Note

Option

Ethernet Function Indication

Connection to SOPAS ET software or OPC server

LC display Status LEDs: “Power,” “Failure,” and “Maintenance request”

Input

Touchscreen

Operation

Via LC display or SOPAS ET software, multiple operating levels, password-protected

Menu language

German, English

Dimensions (W x H x D)

Analyzer cabinet

1,000 mm x 2,100 mm x 652 mm (Details see dimensional drawings)

Weight

Analyzer cabinet

approx. 400 kg