Continuous dust measurement for low and medium concentrations DUSTHUNTER SP100
Highlights • Measuring instrument tested for suitability in accordance with EN 15267 • Particularly suitable for thick-walled or double-walled channels • Low maintenance due to self-monitoring and contamination control • Device version for Ex zone 2/22 or 1/21 Application The DUSTHUNTER SP100 is used to monitor emissions in various fields such as power stations, heating and waste incineration plants, metal processing and cement production. It is also used to monitor filter systems and to measure the dust concentration in flue gas and exhaust air ducts upstream and downstream of dust filters.
DUSTHUNTER SP100
Quality marks and standards
www.endress.com/dusthunter-sp100
Long service life and a high level of measurement reliability MCS200HW
Highlights • Measuring instrument tested for suitability in accordance with EN 15267 • Low-maintenance and effective thanks to wear-free gas delivery • Condition monitoring included Application The MCS200HW is an analyzer system for continuous monitoring of up to 10 IR components plus oxygen and TOC in flue gases. All wetted parts are heated above the dew point and therefore protected against corro sion. The internal reference point check allows the mea sured values to be checked quickly without test gases. The web display and the predefined task wizards make opera tion very easy. MCS200HW Ex offers reliable emissions measurement even in potentially explosive atmospheres.
MCS200HW
Quality marks and standards
www.endress.com/MCS200HW