Level measurement
Overview measuring principles
11
A
Servo
Capacitance
Radiometrics
Hydrostatics (pressure + differential pressure)
–200 to +200°C/ –329 to +392°F 0 to +25bar/ 0 to +362.5psi up to 47m/154ft
–80 to +200°C/ –112 to +392°F –1 to +100bar/ –14.5 to +1,450psi 0.1 to 10m/0.3 to 32ft
Unaffected by temperature and pressure
–70 to +400°C/ –94 to +752°F/ Ambient pressure 420bar/6,090psi (dp)
0.05 to 20m/0.16 to 66ft
• Upt to 0,01 m
(10mbar/0,145 to 700bar/10.150)
• ±4mm/0.02"
•±1% of measuring distance
• ±1% of measuring distance
• Up to ±0.025% of the set span
•Extreme turbulent
• Plastic tank •Extreme conductive build-up
• External radiation (gammagraphy), solution with Gamma Modulator
• Turbulent surfaces
surface (use stilling well) •High viscose medium
•Viscose medium •Build-up
•
• Extreme pressure fluctuations • Extreme build-up
• Density change • Very fast temperature change • agitator (dp)
changing dielectric constants •Conductive build-up
• Viscosity
•Agitator blade • Changing, non
• Non-contact measurement
• Curing build-up •Strong density fluctuations
> 5000mPa s
from outside and, therefore, no application limits • Observe radiation
•Lateral
conductive media or conductivity between
installation or from below
• • Media diffusing through
protection regulations
3 Measurement is possible up to the blocking distance (BD) of the sensor
Made with FlippingBook Digital Proposal Maker