Level measurement
115 Selection according to application
Mechanical conveyor systems
•Monitoring of belt load •Monitoring of feed points •Strong abrasion ( • Fast response times required • Vibration possible
Non-contact
B
Our proposal
Radar Micropilot
Ultrasonics Prosonic
(separated)
(compact)
FMR67B
FMR66B
FMU90/95
FDU93/95
FMU4x
Advantages
• Unaffected by the density of bulk solids, temperature, humidity, filling noise and weather impairment • Purge air connection is standard (FMR67B) • Easy installation with alignment facility •Remote access via Bluetooth® • Heartbeat Technology 2-wire (HART®, PA, Ethernet-APL) ±3mm/±0.12" –40 to +450°C/–40 to +842°F –1 to +16bar/–14.5 to +232psi 1.6 DN 80, DN 100, DN 150, DN 200,
• Separate instrumentation • Self-cleaning effect of sensors • Robust sensor (vibration) • Relay output for point levels • Up to 3 measurements/sec • Easy assembly under conveyor belt derricks (overall size) and above the conveyor belt/crusher 2-/4-wire (4-20mA HART®, DP) ±2mm/±0.08", ±0.2% of measured distance –40 to +150°C/–40 to +302°F +0.7 to +3bar/+10 to +44psi — Threads, flanges (DIN, ANSI, JIS), wall and assembly arm, assembly bracket 45m/148ft
Technical data • Connection •Accuracy • Process temperature* •Process pressure • Min. DC value •Process connection
•Maximum
125m/410ft
measuring range
Application limits
• Risk of build-up formation
use of purge air
• Observe blocking distance •Strong vibration, please use separated instrumentation
* At the process connection
Please note: Radar continued on Page 118
Please note: Ultrasonics continued on Page 126
Made with FlippingBook Digital Proposal Maker