Level measurement
123 Instrument selection within the measuring principle
Guided radar
• • Unaffected by baffles in the silo • Additional safety for measurements by EoP ** evaluation • Safe measurements also during filling
Contact
Levelflex
Levelflex
C
FMP56
FMP57
Typical applications
• Powdery solids • Plastic granulates • High and narrow silos • Reflecting surfaces
• Powdery and grained bulk solids • Plastic granulates •High and narrow silos •Reflecting surfaces • Exchangeable probes (rope) • Coated rope probes (for cereal, flour) •Measurement during filling –1 to +16bar/ –14.5 to +580psi –40 to +150°C/–40 to +302°F
Special features
• Exchangeable probes (rope) • Coated rope probes (for cereal, flour) • Measurement during filling –1 to +16bar/ –14.5 to +232psi –40 to +120°C/–40 to +248°F
Technical data •Process pressure
•Process temperature * •Max. Measuring range rope probe rod probe
12m/39ft — 1.4
45m/148ft 4m/13ft 1.4
• DC value •Accuracy
•Process connection •Process-contacting materials
¾" (G, NPT), adapter flange 304, 1.4301
304, 1.4301
* At the process connection
** The patented End-of-Probe (EoP) algorithm enables Levelflex to provide accurate and reliable level measurement in media with a low DC value (flour, cement, lime, PE granulates, PP granulates and various powders) also during pneumatic filling and fluidized discharge