Level measurement
132 Continuous level measurement in bulk solids
4. Instrument selection within the measuring principle
Electromechanical level system
Required application data • Measuring range • Consider ceiling load by max. tensile force at the point of measurement • Product grain size
Application limits for the electromechanical level system • Temperature up to –20°C/–4°F • Temperature up to +230°C/+446°F • Pressure up to 3bar/43.5psi • (optional 90m/295ft) •
• Pressure and temperature • Resistance requirements • Nozzle height
Recommendation concerning the selection The following aspects should be observed in the selection of the sensing weight: • The sensing weight may neither sink into the product nor slide off the angled surface during the measuring operation • The sensing weight must be able to withstand the chemical properties of the product and the temperature prevailing in the bunker/silo
C
Model
Sensing weight
Application
Temperature
Materials
FMM50 Normal weight, cylindrical with removable spike
Complete temperature range
Steel, stainless steel
ore or stones and granulates Very light and loose bulk
FMM50 Umbrella weight
Max. 150°C/302°F Steel or
stainless steel with Polyester
FMM50 Bag weight
Bunkers with mills downstream
Max. 150°C/302°F Bag made of Polyester, stainless steel
FMM50 Cage weight
Fine-grained bulk solids
Complete temperature range
Steel, stainless steel
FMM50 Oval float FMM50 Bell weight
Granulates
Max. 60°C/140°F Rigid PVC
Light and loose bulk solids
Complete temperature range
Stainless steel
FMM20 Normal weight, cylindrical with removable spike FMM20 Normal weight, cylindrical
Granulates and compacted bulk solids Granulates and compacted bulk solids Very light and loose bulk
Max. 150°C/302°F Steel,
stainless steel
Max. 70°C/158°F Plastics
FMM20 Umbrella weight
Max. 150°C/302°F Steel or
stainless steel with Polyester
FMM20 Bag weight
Bunkers with mills downstream
Max. 150°C/302°F Polyester,
stainless steel
Made with FlippingBook Digital Proposal Maker