Level measurement
14
Continuous level measurement in liquids
3. Selection of the measuring principle according to the application
B
Non-contact
Our proposal Radar Micropilot
Ultrasonics Prosonic
(separated) (compact)
FMU90
FMU4x
FMR5x
FMR6xB
FDU9x
FMU30
Advantages
• For highly viscous media •High resistance • Universally usable (free adjustable measuring range) • Heartbeat Technology •Remote access via Bluetooth® 2-wire (HART®, PA, FF), Ethernet-APL ±1mm/±0.04" –196 to +450°C/–321 to +842°F –1 to +160bar/–14.5 to +2,320psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 80m/262ft
•High resistance • Self-cleaning effect of sensors • Integrated alarm/point level relay •Free adjustable measuring range
Technical data • Connection •Accuracy
2-/4-wire (HART®, DP) ±2mm/±0.08", ±0.2% of the distance
•Process temperature •Process pressure •Process connection
–40 to +105°C/–40 to +221°F +0.7 to +4bar/+10 to +58psi Threads, Tri-Clamp, flanges (DIN, ANSI, JIS)
•Maximum
25m/82ft
measuring range
Application limits
•Strong formation of foam •Many obstacles
guided radar, hydrostatics guided radar, capacitance, hydrostatics hydrostatics
•Strong formation of foam •Vapor pressure
guided radar, hydrostatics radar, guided radar, capacitance
•Many obstacles
guided radar, capacitance, hydrostatics
• Low DC value
Please note: Radar continued on Page 34
Please note: Ultrasonics continued on Page 74
Made with FlippingBook Digital Proposal Maker