Level measurement

16 Continuous level measurement in liquids

3. Selection of the measuring principle according to the application

Non-contact

B

Our proposal Radar Micropilot

Ultrasonics Prosonic

(separated) (compact)

FMU90

FMU4x

FMR10/ FMR20

FMR5x

FMR6xB

FDU9x

FMU30

Advantages

• Non-contact and unaffected by head pressures

•High resistance • Self-cleaning effect of sensors • Integrated alarm/point level relay

• Universally useable due to •Flexible measuring range • Changing, highly viscous or •Remote access via Bluetooth® • Heartbeat Technology

aggressive media (100% PTFE)

Technical data • Connection •Accuracy • Process temperature • Process pressure • Process connection

2-wire (HART®, PA, FF), Ethernet-APL ±1mm/±0.04" –196 to +450°C/–321 to +842°F –1 to +160bar/–14.5 to +2,320psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 80m/262ft

2-/4-wire (HART®, DP) ±2mm/±0.08", +0.2% of the distance

–40 to +105°C/–40 to +221°F +0.7 to +4bar/+10 to +58psi Threads, Tri-Clamp, flanges (DIN, ANSI, JIS) 25m/82ft

•Maximum

measuring range

Application limits

•Strong formation of foam •Many obstacles

guided radar, hydrostatics guided radar, capacitance, hydrostatics hydrostatics

•Strong formation of foam •Vapor pressure

guided radar, hydrostatics radar, guided radar, capacitance guided radar, capacitance, hydrostatics

(20°C/+68°F) •Many obstacles

• Low DC value

Please note: Radar continued on Page 34

Please note: Ultrasonics continued on Page 74

Made with FlippingBook Digital Proposal Maker