Level measurement
58 Continuous level measurement in liquids
4. Instrument selection within the measuring principle
Radar – process industry
Measuring range in dependence on the type of tank, process conditions and medium for Micropilot FMR63B
Process tank with agitator Turbulent surface (e.g. filling from above, agitators, baffles)
C
Antenna
Integrated, PEEK, 20mm/0.75in
PTFE cladded flush mount, 50mm/2 in
PTFE cladded flush mount, 80mm/3in
Cladded, PEEK, 20mm/0.75in
Cladded, PEEK, 40mm/1.5in
FMR63B
Measuring range in m/ft
Media group (DC)
A B C D
A0
A B C D
A0
A B C D
A0 7/ 23
A B C D
7/ 23
7/ 23
1/ 3.3
1/ 3.3
2/ 7
1.5/ 5
1.5/ 5
11/ 36
3/ 10
3/ 10 5/ 16
4/ 13
A0: 1.2 to 1.4 A: 1.4 to 1.9 B: 1.9 to 4 C: 4 to 10 D:
13/ 43
15/ 49
25/ 82
25/ 82
50/ 164
60/ 197