Installation instructions radar – bypass
Weather protection cover • Always recommended for outside installation to avoid strong temperature changes of electronics Optimum horn size • 95mm/3.7") use the next larger antenna and adapt it mechanically
Ball valve • Measurements through an open ball valve with full passage are possible
Measuring range • Measurement is possible up to the tip of the antenna, on principle, however, the end of the measuring range should not be closer than 50mm/2" to the tip of the antenna because of corrosion and build-up formation Recommendations for the bypass • Metallic (without plastic or enamel coating) • • Constant diameter • In transitions, caused for example by ball valves or joining of individual pipe pieces, gaps of max. 1mm/0.04" are permitted
C
60B NMR81 DN40 DN50 DN65 DN50 1 DN50 DN80 PEEK DN50 DN80 Parabol DN100 DN50 DN80 DN100 62B 63B 540
8°
6°
4°
6°
7°
3°
14°
7°
3°
4°
8°
4°
3,5°
3°
1850/ 74
2200/ 87
3200 126
2200/ 87
1850/ 74
3300/ 132
850/ 34
1850/ 74
3300/ 132
50/ 2
430/ 17
50/ 2
430/ 17
430/ 17
* with flooding protection tube
1 Drip-off antenna