Level measurement
70 Continuous level measurement in liquids
4. Instrument selection within the measuring principle
Guided radar – process industry
Levelflex FMP50
Levelflex FMP51
Levelflex FMP52
Technical data • Process pressure
–1 to +40bar/ –14.5 to +580psi –40 to +200°C/ –40 to +392°F
–1 to +40bar/ –14.5 to +580psi –50 to +200°C/ –58 to +392°F
–1 to +6bar/ –14.5 to +87psi –20 to +80°C/ –4 to +176°F
• Process temperature
•Accuracy
• Process connection
G/NPT ¾"
• Wetted parts
Rope/rod: 316L, PPS
Rope: 316, rod and coax: 316L, Alloy C (C22/2.4602), ceramics 0.3 to 10m/1 to 33ft (rod), 1 to 45m/3.2 to 148ft (rope), 0.3 to 6m/1 to 20ft (coax) Optional TI01001F
PTFE, PFA 0.3 to 4m/1 to 13ft (rod), 1 to 45m/3.2 to 148ft (rope) Optional TI01001F
C
• Measuring ranges
0.3 to 4m/1 to 13ft (rod), 0.3 to 12m/1 to 39ft (rope) — TI01000F
• Gastight feedthrough • Technical Information Applications Horizontal storage tank cyl.
O + O + – + O – – –
+*
O + + O – O O – –
Vertical storage tank
+ + O – + + – –
Buffer tank
Recipient tank Process tank
Stilling well
Bypass
Pump shaft
Channel measurement Interface measurement
+**
+**
Application limits
• Aggressive media •High pressure/ tempera tures
FMP52
• Aggressive media • Interface with emulsion
FMP52
• High process temperatures
FMP54
FMP51, FMP54
FMP55
Possible
diffusion through the probe coating Limited lifetime • Interface with emulsion
176°F; 6bar/87psi
FMP55
+ = recommended
O = restricted (observe limits)
– = not recommended