Level measurement
Instrument selection within the measuring principle
81
Capacitance – process industry
Liquicap FMI51
Liquicap FMI52
Liquicap FMI21
Technical data •Process pressure
–1 to +100bar/ -14.5 to +1,450psi –80 to +200°C/ –112 to +392°F ±1%
–1 to +100bar/ -14.5 to +1,450psi –80 to +200°C/ –112 to +392°F ±1%
–1 to +10bar/ -14.5 to +145psi –40 to +100°C/ –40 to +212°F ±1%
C
•Process temperature
•Accuracy •Process connection
EN, ANSI, JIS, hygienic 316L, PFA, PTFE Rod probe up to 4m/13ft Optional TI00401F
EN, ANSI, JIS, hygienic 316L, PFA, FEP Rope probe up to 10m/32ft Optional TI00401F
• Wetted parts • Measuring ranges • Gastight feedthrough • Technical Information Applications Horizontal storage tank cyl.
316L, PP, carbon fiber up to 2.5m/8.2ft — TI00393F
+ + + + + + + O – +
0 + – – – O O O – +
+ + – – – – – O – –
Vertical storage tank
Buffer tank
Recipient tank Process tank
Stilling well
Bypass
Pump shaft
Channel measurement Interface measurement
Application limits
• Insufficient clearance towards ceiling • Changing, non conductive media or conductivity between
• Changing, non-conductive media or conductivity
• Changing, non conductive media or conductivity between
• Highly viscous liquids
+ = recommended
O = restricted (observe limits)
– = not recommended
Made with FlippingBook Digital Proposal Maker