Level measurement

Instrument selection within the measuring principle

85

Proservo NMS80

Proservo NMS81

Proservo NMS83

0.2 to +6bar/3 to +87psi –200 to +200°C/–328 to +392°F ±0.4mm/0.02"

0 to +25bar/0 to +362.5psi –200 to +200°C/–328 to +392°F ±0.4mm/0.02"

0 to +6bar/0 to +87psi –200 to +200°C/–328 to +392°F ±0.4mm/0.02"

316L, Alloy C276, PTFE 36m/118ft Standard TI01248G

316L, Alloy C276, PTFE 47m/154ft Standard TI01249G

316L, 316 polished, PTFE 22m/72ft Standard TI01250G

C

+ + – – – + – – –

+ + – – – + – – –

+ + – – – + – – –

• Turbulent condition

Guide wires or stilling well PTFE displacer or NMR81

• Turbulent condition

Guide wires or stilling well PTFE displacer or NMR81

• Turbulent condition

Guide wires or stilling well PTFE displacer or NMR81

•High viscosity • Requires min. difference of 0.100g/ml between layers

•High viscosity • Requires min. difference of 0.100g/ml between layers

•High viscosity • Requires min. difference of 0.100g/ml between layers

+ = recommended

O = restricted (observe limits)

– = not recommended