Tank and Terminal Management

26

Tank and Terminal Management

3URGXFWV DQG 6HUYLFHV Products

(QGUHVV +DXVHU R̟ HUV D FRPSUHKHQVLYH UDQJH RI PHDVXUHPHQW LQVWUXPHQWV ZLWK DQ LQVWUXPHQWDWLRQ VROXWLRQ WR VXLW HYHU\ WDQN HQYLURQPHQW DQG DFFXUDF\ OHYHO UHTXLUHPHQW +RZHYHU LQ RUGHU WR UHDFK VWDQGDUG YROXPH RU WR FRPSDUH PDVV ÀJXUHV temperature, expansion functions easily, more aspects should be considered. An Endress+Hauser tank monitoring or gauging system includes all of the elements to allow you to manage and optimize your inventory accurately and safely. From consultation, planning and training through to service, repairs and spares, a comprehensive array of service solutions completes Endress+Hauser’s customer-focused spectrum of activities.

Tank Gauging devices (custody transfer)

Radar (free space) Micropilot S p )

Radar (stilling well) Micropilot S

Servo Proservo

FMR540

FMR532

NMS5

Advan tages

‡ 8QD̟ HFWHG E\ KHDG SUHVVXUH ‡ 8QD̟ HFWHG E\ WKH YLVFRVLW\ RI WKH media

‡ 8QD̟ HFWHG E\ KHDG SUHVVXUH ‡ 8QD̟ HFWHG E\ WKH YLVFRVLW\ RI WKH media

‡ Level, density and interface with one device ‡ 8QD̟ HFWHG E\ QR]]OH GLPHQVLRQ DQG tank obstacles

‡ 8QD̟ HFWHG E\ JDV SKDVH ‡ 8QD̟ HFWHG E\ '. YDOXH

Appli cation obser vations

‡ Weights & Measures approval

ˆ &KHFN \RXU local approvals (no NMi/PTB IRU OLTXHÀHG gases) ˆ 3URVHUYR

‡ Weights & Measures approval

ˆ &KHFN \RXU ORFDO approvals (no NMi/PTB for OLTXHÀHG JDVHV ˆ 3URVHUYR

‡ Weights & Measures approval ‡ Turbulent surfaces

ˆ &KHFN \RXU

local approvals

ˆ 8VH JXLGH ZLUHV stilling well Micropilot S ˆ 0LFURSLORW 6

‡ Larger error caused by gas phase ‡ Low DK value (<1.6) ‡ Bad stilling well ‡ Large changes in stilling well cross section ‡ Stilling well 150mm

‡ Larger error caused by gas phase ‡ Low DK value (<1.6) ‡ Close to tank wall installations

GXULQJ ÀOOLQJ ‡ Highly viscous media

ˆ 3URVHUYR

ˆ 3URVHUYR

ˆ 3URVHUYR /HYHOÁH[ ˆ 3URVHUYR /HYHOÁH[ ˆ 3URVHUYR /HYHOÁH[

ˆ 3URVHUYR /HYHOÁH[

Inventory devices

Guided radar /HYHOÁH[

Radar Micropilot M

Average temperature Prothermo ure

FMP5x

FMR2xx

NMT539

Advan tages

‡ 8QD̟ HFWHG E\ QR]]OH GLPHQVLRQV and tank obstacles

‡ 8QD̟ HFWHG E\ KHDG SUHVVXUH ‡ 8QD̟ HFWHG E\ WKH YLVFRVLW\ RI WKH media

‡ 8QD̟ HFWHG E\ KHDG SUHVVXUH ‡ 8QD̟ HFWHG E\ WKH YLVFRVLW\ RI WKH media

Appli cation obser vations

‡ Gas phase

ˆ 3URVHUYR

‡ Weights & Measures approval

ˆ &KHFN \RXU ORFDO approvals (no NMi/PTB for liquefied gases) ˆ 3URVHUYR

‡ Weights & Measures approval ‡ Pressurized tanks

ˆ &KHFN \RXU

error 0.7%/m

local approvals

‡ Weights & Measures approval ‡ Strong build-up formation,

ˆ &KHFN \RXU

local approvals (no NMi/PTB)

ˆ 8VH

‡ Larger error caused by gas phase ‡ Low DK value (<1.4) ‡ Close to tank wall installations

thermowells

ˆ 0LFURSLORW 6

ˆ 3URVHUYR

high-viscosity, crystallizing media

ˆ 3URVHUYR Levelflex

Made with FlippingBook - professional solution for displaying marketing and sales documents online