Guide to analyzers, sensors and samplers
Parameter Typical applications
Device
Ranges
Aluminum
Liquiline System CA80AL
10 - 1,000 µg/l
Al
• Water treatment
NH 4 -N NH 4 -N NH 4 -N
Ammonium • Water treatment • Wastewater • Boiler feedwater
Liquiline System CA80AM 0 - 20 mg/l
0.5 - 50 mg/l 1 - 100 mg/l
NH 4 -N
ISEmax CAS40D/CM44
0.1 - 1,000 mg/l
• Wastewater: optimization of nitrification/denitrification
APHA Hazen
Memosens Wave CAS80E/ CM44
2 mm OPL 10 mm OPL 50 mm OPL
0 - 12,500 Hazen 0 - 2,500 Hazen 0 - 500 Hazen BODeq Equiv. KHP BODeq Equiv. KHP BODeq Equiv. KHP 0 - 5,000 BODeq 0 - 1,000 BODeq 0 - 200 BODeq 0 - 450 BODeq 0 - 90 BODeq 0 - 18 BODeq 0 - 750 BODeq 0 - 150 BODeq 0 - 30 BODeq COD + dilution module (1:4) CODeq Equiv. KHP CODeq Equiv. KHP CODeq Equiv. KHP 0 - 3000 CODeq 0 - 600 CODeq 0 - 120 CODeq 0 - 20,000 CODeq 0 - 4000 CODeq 0 - 800 CODeq Cr (VI) Cr (VI) COD
• Outlets of wastewater treatment plants • Drinking water
BOD (biological oxygen demand)
Viomax CAS51D (SAC)/ CM44
0 - 75 mg/l 0 - 375 mg/l 0 - 1,500 mg/l
• Drinking water • Surface water
• Outlets of wastewater treatment plants • Inlets of wastewater treatment plants
Memosens Wave CAS80E 2 mm OPL
• Inlets of wastewater treatment plants
10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL
• Outlets of wastewater treatment plants
• Surface water
Chromate
Liquiline System CA80CR 0.03 - 2.5 mg/l
• Industrial wastewater • Process water
0.2 - 5 mg/l
COD (chemical oxygen demand)
Liquiline System CA80COD 0 - 5,000 mg/l
• Raw wastewater, inflow and outflow monitoring • Raw wastewater, load control • Industrial discharger monitoring • Monitoring of cooling water
0 - 5,000 mg/l
Viomax CAS51D (SAC)/ CM44
0.15 - 75 mg/l 0.75 - 370 mg/l 2.5 - 1,000 mg/l
Memosens Wave CAS80E/ CM44
2 mm OPL 10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL
• Outlets of wastewater treatment plants
• Inlets of wastewater treatment plants
Hardness
Liquiline System CA80HA 0 - 80 mg/l
CaCO 3
• Monitoring of softening processes in water and drinking water treatment
Iron
Liquiline System CA80FE 0.05 - 2.5 mg/l
Fe Fe
• Drinking water • Wastewater • Mineral well
0.1 - 5 mg/l
0.1 - 50 mg/l NO 3 -N 0.4 - 200 mg/l NO 3 0.01 - 20 mg/l NO 3 -N 0.04 - 80 mg/l NO 3 0 - 2500 mg/l NO 3 -N 0 - 500 mg/l NO 3 -N 0 - 100 mg/l NO 3 -N
Nitrate
Viomax CAS51D/CM44
2 mm OPL
• Drinking water • Outlet monitoring of wastewater treatment plants • Monitoring and optimization of denitrification
8 mm OPL
Memosens Wave CAS80E/ CM44
2 mm OPL 10 mm OPL 50 mm OPL
NO 3 -N
ISEmax CAS40D/CM44
0.1 - 1,000 mg/l
• Wastewater: optimization nitrification/denitrification