Analyzers, in-situ sensorsand samplers

50

Experts in liquid analysis

Guide to analyzers, sensors and samplers

Parameter Typical applications

Device

Ranges

Aluminum

Liquiline System CA80AL

10 - 1,000 µg/l

Al

• Water treatment

NH 4 -N NH 4 -N NH 4 -N

Ammonium • Water treatment • Wastewater • Boiler feedwater

Liquiline System CA80AM 0 - 20 mg/l

0.5 - 50 mg/l 1 - 100 mg/l

NH 4 -N

ISEmax CAS40D/CM44

0.1 - 1,000 mg/l

• Wastewater: optimization of nitrification/denitrification

APHA Hazen

Memosens Wave CAS80E/ CM44

2 mm OPL 10 mm OPL 50 mm OPL

0 - 12,500 Hazen 0 - 2,500 Hazen 0 - 500 Hazen BODeq Equiv. KHP BODeq Equiv. KHP BODeq Equiv. KHP 0 - 5,000 BODeq 0 - 1,000 BODeq 0 - 200 BODeq 0 - 450 BODeq 0 - 90 BODeq 0 - 18 BODeq 0 - 750 BODeq 0 - 150 BODeq 0 - 30 BODeq COD + dilution module (1:4) CODeq Equiv. KHP CODeq Equiv. KHP CODeq Equiv. KHP 0 - 3000 CODeq 0 - 600 CODeq 0 - 120 CODeq 0 - 20,000 CODeq 0 - 4000 CODeq 0 - 800 CODeq Cr (VI) Cr (VI) COD

• Outlets of wastewater treatment plants • Drinking water

BOD (biological oxygen demand)

Viomax CAS51D (SAC)/ CM44

0 - 75 mg/l 0 - 375 mg/l 0 - 1,500 mg/l

• Drinking water • Surface water

• Outlets of wastewater treatment plants • Inlets of wastewater treatment plants

Memosens Wave CAS80E 2 mm OPL

• Inlets of wastewater treatment plants

10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL

• Outlets of wastewater treatment plants

• Surface water

Chromate

Liquiline System CA80CR 0.03 - 2.5 mg/l

• Industrial wastewater • Process water

0.2 - 5 mg/l

COD (chemical oxygen demand)

Liquiline System CA80COD 0 - 5,000 mg/l

• Raw wastewater, inflow and outflow monitoring • Raw wastewater, load control • Industrial discharger monitoring • Monitoring of cooling water

0 - 5,000 mg/l

Viomax CAS51D (SAC)/ CM44

0.15 - 75 mg/l 0.75 - 370 mg/l 2.5 - 1,000 mg/l

Memosens Wave CAS80E/ CM44

2 mm OPL 10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL

• Outlets of wastewater treatment plants

• Inlets of wastewater treatment plants

Hardness

Liquiline System CA80HA 0 - 80 mg/l

CaCO 3

• Monitoring of softening processes in water and drinking water treatment

Iron

Liquiline System CA80FE 0.05 - 2.5 mg/l

Fe Fe

• Drinking water • Wastewater • Mineral well

0.1 - 5 mg/l

0.1 - 50 mg/l NO 3 -N 0.4 - 200 mg/l NO 3 0.01 - 20 mg/l NO 3 -N 0.04 - 80 mg/l NO 3 0 - 2500 mg/l NO 3 -N 0 - 500 mg/l NO 3 -N 0 - 100 mg/l NO 3 -N

Nitrate

Viomax CAS51D/CM44

2 mm OPL

• Drinking water • Outlet monitoring of wastewater treatment plants • Monitoring and optimization of denitrification

8 mm OPL

Memosens Wave CAS80E/ CM44

2 mm OPL 10 mm OPL 50 mm OPL

NO 3 -N

ISEmax CAS40D/CM44

0.1 - 1,000 mg/l

• Wastewater: optimization nitrification/denitrification

Made with FlippingBook - professional solution for displaying marketing and sales documents online