Analyzers, in-situ sensorsand samplers
Analyzers and samplers in water treatment
51
Parameter Typical applications
Device
Ranges
Nitrite
Liquiline System CA80NO 10 - 500 µg/l
NO 2 -N NO 2 -N NO 2 -N
• Water treatment • Wastewater
0.1 - 1 mg/l 0.2 - 3 mg/l 0 - 2.5 mg/l 0.05 - 10 mg/l 0.5 - 20 mg/l 0.5 - 50 mg/l 0.1 - 50 m -1 0.5 - 250 m -1 1.5 - 700 m -1
PO 4 -P (blue method) PO 4 -P (blue method) PO 4 -P (yellow method) PO 4 -P (yellow method)
Phosphate
Liquiline System CA80PH
• Wastewater • Drinking water • Boiler water • Cooling tower water
Viomax CAS51D/CM44
SAC SAC SAC
SAC 254 (spectral
• Continuous monitoring of wastewater for organic pollution • Special measuring tasks in UV range
absorption coefficient)
• Surface water • Drinking water
Memosens Wave CAS80E/ CM44
2 mm OPL 10 mm OPL 50 mm OPL
0 - 1000 1/m SAC 0 - 200 1/m SAC 0 - 40 01/m SAC
Silica
Liquiline System CA80SI
0 - 500 µg/l (ppb) Si 50 - 5,000 µg/l (ppb) Si
• Power plants: Boiler feedwater, feedwater return from condensers, ion exchanger outlet • Power plants: Boiler feedwater, feedwater returning from condensers, ion exchanger outlets, feedwater from desalination plants
Sodium
CA76NA
0.1 - 9,999 µg/l (ppb) Na
Total nitrogen
Liquiline System CA80TN 0 - 10 mg/l
N tot N tot N tot
• Wastewater • Surface water
0 - 50 mg/l 0 - 200 mg/l
TOC (total orga nic carbon)
CA78
0.5 - 1000 µg/l
TOC
• Deionized water in power plants • Deionized water in disinfectant production • Ultrapure water in semiconductor production
CA79
0.5 - 1000 µg/l
TOC
• Ultrapure water in the pharmaceutical industry • Water for injection
TOCII CA72TOC
0.25 - 600 mg/l 1 - 2,400 mg/l 2.5 - 6,000 mg/l 5 - 12,000 mg/l 0.06 - 30 mg/l 0.3 - 150 mg/l 0.9 - 410 mg/l
TOC TOC TOC TOC
• Municipal water containing solids • Very polluted industrial wastewater • Chemical industry
Viomax CAS51D (SAC)/ CM44
TOCeq Equiv. KHP TOCeq Equiv. KHP TOCeq Equiv. KHP
• Continuous monitoring of wastewater for organic loads
• Surface water • Drinking water
Memosens Wave CAS80E/ CM44
2 mm OPL 10 mm OPL 50 mm OPL 2 mm OPL 10 mm OPL 50 mm OPL
0 - 1200 TOCeq 0 - 240 TOCeq 0 - 48 TOCeq 0 - 8000 TOCeq 0 - 400 TOCeq 0 - 80 TOCeq (blue method) (blue method)
• Continuous monitoring of the outlets of wastewater treatment plants for organic loads
• Drinking water
Total phosphorus
Liquiline System CA80TP 0 - 10 mg/l P tot
• Wastewater • Boiler feedwater • Cooling tower water
0.5 - 50 mg/l P tot
Sampling
Liquistation CSF28 Liquistation CSF48 Liquiport 2010 CSP44
• Inlets of wastewater treatment plants • Outlets of wastewater treatment plants