Level measurement
Selection according to application
19
Buffer tank
• filling from above, mixing jets, slowly turning mixer, lateral installation) • Measurement without stilling well •Foam spots, islands • Pressurized • Fast temperature changes (cleaning)
Contact
B
Hydrostatics Cerabar, Deltabar
Guided radar Levelflex
Capacitance Liquicap
FMD71/FMD72 (electronic dp)
FMP5x
FMI5x
PMD55B, PMD75B, PMD78B
• Unaffected by foam • Unaffected by installation situation • Unaffected by DC value • Electronic dp • Remote access via Bluetooth® • Heartbeat Technology 2-wire (HART®, PA, FF) ±0.035% of the set span –70 to +400°C/–94 to +752°F up to +40bar/+580psi Threads, flanges (DIN, ANSI, JIS), hygienic connections Typically up to 100m/328ft
• Unaffected by nozzle dimensions and tank obstacles • Unaffected by agitated surfaces • Heartbeat Technology
• For small tanks with fast filling and discharging operations • Unaffected by nozzle dimensions and tank obstacles • No blocking distance
2-wire (HART®) ±1.0% –80 to +200°C/–112 to +392°F –1 to +100bar/–14.5 to +1,450psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 4m/13ft (rod), 10m/32ft (rope)
2-wire (HART®, PA, FF), 4-wire HART® ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +400bar/–14.5 to +5,800psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 10m/33ft (rod), 45m/148ft (rope), 6m/20ft (coax), longer upon request
•Density change
guided radar, radar, ultrasonics radar, ultrasonics, bubble system radar, guided radar, dp
• Strong lateral load
radar, ultrasonics, hydrostatics radar, ultrasonics
• Changing,
guided radar, radar, ultrasonics
non-conductive media or conductivity between
•Strong build up formation
• Strong build-up
high viscosity, crystallizing media, etc.) • DC starting at 1.4
•Strong,
•Ratio head pressure to
radar, ultrasonics
conductive build up formation
level max. 6:1 for electronic dp
hydrostatics
•Strong lateral load
radar, ultrasonics, hydrostatics
Please note: Hydrostatics continued on Page 88
Please note: Guided radar continued on Page 68
Please note: Capacitance continued on Page 80
Made with FlippingBook Digital Proposal Maker