Level measurement
Selection according to application
21
• Pressurized • Fast temperature changes (cleaning) • Fast filling and discharging operations • • Strongly foaming surface
Contact
Our proposal Capacitance Liquicap
B
Guided radar Levelflex
Hydrostatics Deltapilot, Deltabar, Cerabar
2 x FMB50/ FMB70
FMI5x
FMP5x
FMD71/FMD72
2 x PMC/PMP51B, 2 x PMC/PMP71B
• Fastest response times during filling and discharging operations • Maximum tank exploitation – no blocking distance • Unaffected by nozzle dimensions and tank baffles 2-wire (HART®) ±1.0% –80 to +200°C/–112 to +392°F –1 to +100bar/–14.5 to +1,450psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 4m/13ft (rod), 10m/32ft (rope)
• Unaffected by nozzle dimensions and tank obstacles • Unaffected by product properties
• Electronic dp • Unaffected by foam • Unaffected by installation situation • Unaffected by DC value • Fast response times • Unaffected by ambient temperatures 2-wire (HART®, PA, FF) ±0.05% of the set span –40 to +150°C/–40 to +302°F up to +40bar/+580psi Threads, flanges (DIN, ANSI, JIS), hygienic connections Typically up to 100m/328ft
(conductivity, density) • Heartbeat Technology
2-wire (HART®, PA, FF), 4-wire HART® ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +400bar/–14.5 to +5,800psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 10m/33ft (rod), 45m/148ft (rope), 6m/20ft (coax), longer upon request
• Changing, non conductive media or
hydrostatics
• Extremely fast filling and
capacitance
•Density change • Electronic
capacitance
discharging operations (response times
capacitance, guided radar
dp-ratio head pressure to level max. 6:1
conductivity between 1 to
• Highly accurate measurements in the lower and upper area • DC starting at 1.4
capacitance
hydrostatics
Please note: Capacitance continued on Page 80
Please note: Guided radar continued on Page 68
Please note: Hydrostatics continued on Page 88
Made with FlippingBook Digital Proposal Maker