Level measurement

26 Continuous level measurement in liquids

3. Selection of the measuring principle according to the application

B

Non-contact

Our proposal Radar Micropilot

Radar Micropilot

FMR54

FMR62B

Advantages

• Measurement with ball valve possible • For highly viscous media (100% PTFE possible) • Universally usable (free adjustable measuring range) •Remote access via Bluetooth® • Heartbeat Technology

• Non-contact and unaffected by head pressures • Universally useable due to flexible measuring range • Also with ball valve •Remote access via Bluetooth® • Heartbeat Technology 2-wire (HART®, PA, Ethernet-APL) ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +160bar/–14.5 to +2,320psi Threads, flanges (DIN, ANSI, JIS),

Technical data • Connection •Accuracy • Process temperature • Process pressure • Process connection

2-wire (HART®, PA, FF) ±2mm/±0.08"

–196 to +450°C/–321 to +842°F –1 to +160bar/–14.5 to +2,320psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 70m/229ft

•Maximum

70m/229ft

measuring range

Application limits

• Strong formation of foam •Many obstacles

guided radar, hydrostatics guided radar, capacitance, hydrostatics hydrostatics

•Strong formation of foam • Low DC value

guided radar, hydrostatics hydrostatics

• Bypass > 12 m

FMR54

Please note: Radar continued on Page 34

Made with FlippingBook Digital Proposal Maker