Stilling well
• Measurement in metal pipes (installed in the tank)
•
Contact
B
Our proposal Guided radar Levelflex
Capacitance Liquicap
FMP5x
FMI5x
• Unaffected by the stilling well geometry • Divisible rod probe • Heartbeat Technology
• Unaffected by the stilling well geometry
2-wire (HART®, PA, FF), 4-wire HART® ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +400bar/–14.5 to +5,800psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 10m/33ft (rod), 45m/148ft (rope), longer upon request
2-wire (HART®) ±1.0% –80 to +200°C/–112 to +392°F –1 to +100bar/–14.5 to +1,450psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 4m/13ft (rod), 10m/32ft (rope)
• Contact between probe and stilling well • Highly viscous products •Max. stilling well length 10m/33ft • DC starting at 1.4
radar, ultrasonics
• Changing, non
guided radar, radar, ultrasonics
conductive media or conductivity between
radar, ultrasonics float