Level measurement

Selection according to application

25

Stilling well

• Measurement in metal pipes (installed in the tank)

Contact

B

Our proposal Guided radar Levelflex

Capacitance Liquicap

FMP5x

FMI5x

• Unaffected by the stilling well geometry • Divisible rod probe • Heartbeat Technology

• Unaffected by the stilling well geometry

2-wire (HART®, PA, FF), 4-wire HART® ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +400bar/–14.5 to +5,800psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 10m/33ft (rod), 45m/148ft (rope), longer upon request

2-wire (HART®) ±1.0% –80 to +200°C/–112 to +392°F –1 to +100bar/–14.5 to +1,450psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 4m/13ft (rod), 10m/32ft (rope)

• Contact between probe and stilling well • Highly viscous products •Max. stilling well length 10m/33ft • DC starting at 1.4

radar, ultrasonics

• Changing, non

guided radar, radar, ultrasonics

conductive media or conductivity between

radar, ultrasonics float

Please note: Guided radar continued on Page 68

Please note: Capacitance continued on Page 80

Made with FlippingBook Digital Proposal Maker