Level measurement

28 Continuous level measurement in liquids

3. Selection of the measuring principle according to the application

B

Non-contact

Our proposal

Ultrasonics Prosonic

Radar Micropilot

(separated)

(compact)

FMU90

FMU4x

FMR20 FMR10

FMR60B

FDU9x

Advantages

• Overspill-protected, heated sensors with self cleaning effect • Universal use due to flexible measuring range • Operation and display at easily accessible mounting locations possible incl. integrated point level relay and integrated control functions

• Universally usable (free adjustable measuring range) • Unaffected by temperature layers • Free of maintenance •Remote indicator and control •Remote access via Bluetooth® 2-wire (HART®, PA, Modbus, Ethernet-APL) ±2mm/±0.08" –40 to +130°C/–40 to +266°F –1 to +3bar/–14.5 to +43psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 40m/130ft

Technical data • Connection

2-/4-wire (HART®, DP)

•Accuracy • Process temperature • Process pressure • Process connection

±2mm/±0.08", +0.2% of the distance –40 to +105°C/–40 to +221°F +0.7 to +4bar/+10 to +58psi Threads, Tri-Clamp, flanges (DIN, ANSI, JIS)

•Maximum

25m/82ft

measuring range

Application limits

• Strong formation of foam •Many obstacles

•Strong

ultrasonics, hydrostatics hydrostatics

hydrostatics

condensation

• Icing of the antenna

Please note: Ultrasonics continued on Page 74

Please note: Radar continued on Page 34

Made with FlippingBook Digital Proposal Maker