Level measurement
Selection according to application
29
Pump shaft/overfall construction/ rain water basin
•Many obstacles • Risk of flooding, foam formation and turbulent surfaces • Build-up on the sensor and contacting obstacles (ice formation in winter, suspended solids) • Installation at open basins or underground • Sludge formation due to suspended solids
B
Contact
Our proposal Hydrostatics Deltapilot/Waterpilot
Capacitance Liquicap
FMB53
FMX21
FMI5x
• Unaffected by tank baffles, mounting situation and foam • Operation and display possible at easily accessible mounting locations
• For small tanks with fast filling and discharging operations • Unaffected by nozzle dimensions and tank obstacles •No blocking distance
2-wire (analog, HART®, PA, FF)
2-wire (HART®)
±0.1% –10 to +80°C/+14 to +176°F +0,1 to +20bar/1.45 to 290psi Mounting clamp, cable mounting screw
±1.0% –80 to +200°C/–112 to +392°F –1 to +100bar/–14.5 to +1,450psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 4m/13ft (rod), 10m/32ft (rope)
200m/656ft (20bar/290psi)
• Risk of sludge formation/pollution (build-up)
ultrasonics, radar
• Changing, non
guided radar, radar
conductive media or conductivity between •Strong, conductive build-up formation
radar, hydrostatics
Please note: Hydrostatics continued on Page 88
Please note: Capacitance continued on Page 80
Made with FlippingBook Digital Proposal Maker