Level measurement

40 Continuous level measurement in liquids

4. Instrument selection within the measuring principle

Radar – Tank Gauging

Micropilot FMR532 6GHz/custody transfer

Micropilot FMR540 26GHz/custody transfer

Technical data • Process pressure • Process temperature •Accuracy • Process connection • Wetted parts • Measuring ranges • Gastight feedthrough • Technical Information Applications Horizontal storage tank cyl.

–1 to +40bar/–14.5 to +580psi –40 to +150°C/–40 to +302°F ±1mm/±0.04" 316Ti/1.4571, PTFE, 316L/ 1.4435, HNBR, sealings 25m/82ft Standard TI00344F

–1 to +16bar/–14.5 to +232psi –40 to +200°C/–40 to +392°F ±1mm/±0.04"

C

316L/1.4435, PTFE, PEEK, sealings

40m/131ft Standard TI00412F

– O – – – + – – –

– + – – – – – – –

Vertical storage tank

Buffer tank

Recipient tank Process tank

Stilling well

Bypass

Pump shaft

Channel measurement

Application limits

• Free space and many baffles

FMR540 •Stilling wells

FMR532

+ = recommended

O = restricted (observe limits)

– = not recommended