Level measurement
76 Continuous level measurement in liquids
4. Instrument selection within the measuring principle
Ultrasonics – process industry
Prosonic FMU30
Prosonic FMU40/41
Prosonic FMU42, FMU44
Technical data • Process pressure
+0.7 to +3bar/ +10 to +44psi
+0.7 to +3bar/ +10 to +44psi –40 to +80°C/–40 to +176°F ±2mm/±0.08" or 0.2% of distance
+0.7 to +2.5bar/ +10 to +36psi –40 to +80°C/–40 to +176°F ±4mm/±0.16" or 0.2% of distance 80 (100)/100 (150/200) PVDF/EPDM/Viton 0.4 to 10m/1.3 to 32ft (FMU42) 0.5 to 20m/1.6 to 65ft (FMU44) — TI01458F/TI01460F
• Process temperature •Accuracy
–20 to +60°C/–4 to +140°F ±3mm/±0.12" or 0.2% of distance
• Process connection
• Wetted parts • Measuring ranges
PP/EPDM 0.25 to 5m/0.8 to 16ft 0.35 to 8m/1.1 to 26ft (2") — TI00440F
PVDF/EPDM 0.25 to 5m/0.8 to 16ft (FMU40) 0.35 to 8m/1.1 to 26ft (FMU41) — TI01456F/TI01457F
• Point level detection • Technical Information
C
Applications
2"
FMU40
FMU41
FMU42
FMU44
Horizontal storage tank cyl
+
O
+
O
O
–
Vertical storage tank
+
+
+
+
+
+
Buffer tank
–
–
+
O
–
–
Recipient tank
–
–
–
–
–
–
Process tank
O
O
+
+
+
+
Stilling well
O
O
+
+
+
+
Bypass
–
–
–
–
–
–
Pump shaft
O
O
O
O
O
O
Channel measurement
O
O
O
O
O
O
Application limits
•For higher resistance •Foam/ strong turbulence possible •Fast filling and discharging rate • Point level detection
FMU42, FDU9x FMU30 (2"), FMU42, FDU91 FMU90 + FDU9x
•For higher resistance •Foam/ strong turbulence possible •Fast filling and discharging rate • Point level detection
FMU42, FDU9x FMU41, FMU42/ FDU91 FMU90 + FDU9x
•Foam/ strong
FMU44/ FDU92
turbulence possible
•Fast
FMU90 + FDU9x
filling and discharging rate • Point level detection
FMU90 + FDU9x
FMU90 + FDU9x
FMU90 + FDU9x
+ = recommended
O = restricted (observe limits)
– = not recommended
Made with FlippingBook Digital Proposal Maker