Level measurement

Instrument selection within the measuring principle

91

Cerabar PMC71B

Cerabar PMP71B

Deltapilot FMB70

100mbar to 40bar/ 1.5 to 600psi

400mbar to 700bar/ 6 to 10,500psi –70 to +400°C/ –94 to +752°F ±0.05% (0.025% optional) Thread, flange, hygienic connections 316L, Alloy, Tantal, Monel, Gold Standard Metal welded

100mbar to 10bar/ 1.5 to 145psi

–40 to +150°C/ –40 to +302°F ±0.05% (0.025% optional) Thread, flange, hygienic connections 316L, Al 2 O 3 , sealings, PVDF

–10 to +100°C/ +14 to +212°F ±0.1% (0.075% optional) Thread, flange, hygienic connections 316L, Alloy Standard Contite, condensate-proof, water-tight, metal welded TI00416P

C

Standard Ceramics

TI01507P

TI01509P

O + O + O – – – –

O + O – O – – – –

O + O O O – – – –

• If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure to hydrostatic pressure

• If pressurized, possibly use differential pressure

• If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure to hydrostatic pressure

measurement with two pressure transmitters. Observe ratio head pressure to hydrostatic pressure

Made with FlippingBook Digital Proposal Maker