Level measurement
92 Continuous level measurement in liquids
4. Instrument selection within the measuring principle
Hydrostatics – process industry
Waterpilot FMX11/FMX21
Deltapilot FMB51/52/53
Deltabar PMD55B
Technical data • Process pressure
100mbar to 20bar 0.15 to 290psi –10 to +70°C/ +14 to +158°F ±0.2% (0.1% optional) Mounting clamp, cable mounting screw 316L, Al 2 O 3 , FKM, EPDM, PE, FEP, PUR — Ceramics
100mbar to 10bar/ 0.07 to 150psi –10 to +85°C/ +14 to +185°F ±0.2% (0.1% optional)
30mbar to 40bar/ 0.45 to 600psi –40 to +110°C/ –40 to +230°F ±0.075% (0.055% optional)
• Process temperature
C
•Accuracy
• Process connection
Thread, flange
• Wetted parts
316L, Alloy, PE, FEP
316L, Alloy
— Contite, condensate-proof, water-tight, metal welded TI00437P
— Metal welded
• Gastight feedthrough • Measuring cell
• Technical Information Applications Horizontal storage tank cyl.
TI00351P/TI00431P
TI01510P
– – – – – O – + +
+ + O O – – – + +
O O + – + – O – –
Vertical storage tank
Buffer tank
Recipient tank Process tank
Stilling well
Bypass
Pump shaft
Channel measurement
Application limits
• Pressurized tanks
• Pressurized tanks • FMB51: Rope variant FMB52: Rod variant
• Impulse-piping required • If pressurized, possibly use Deltabar FMD71/FMD72
electronic dp. Observe ratio head pressure to hydrostatic pressure
+ = recommended
O = restricted (observe limits)
– = not recommended
Made with FlippingBook Digital Proposal Maker