Level measurement

Selection according to application

23

Process tank with agitator

•Agitated surface • • Pressurized • Free space measurement (without stilling well/bypass) •Foam formation is possible depending on the application

Contact

B

Our proposal Hydrostatics Deltabar

PMD55B, PMD75B, PMD78B

FMD71/FMD72 (electronic dp)

• Unaffected by DC values • Unaffected by tank baffles • Unaffected by foam • Unaffected by strongly fluctuating ambient temperatures •Remote access via Bluetooth® • Heartbeat Technology 2-wire (HART®, PA, FF) ±0.035% of the set span –70 to +400°C/–94 to +752°F up to +40bar/+580psi Threads, flanges (DIN, ANSI, JIS), hygienic connections Typically up to 100m/328ft

• Density change •Strong build-up formation

radar, ultrasonics radar, ultrasonics, bubble system

Please note: Hydrostatics continued on Page 88

Made with FlippingBook Digital Proposal Maker