24 Continuous level measurement in liquids
3. Selection of the measuring principle according to the application
Non-contact
B
Our proposal Radar Micropilot
Ultrasonics Prosonic
(separated)
(compact)
FMU90
FDU9x
FMR54
FMR62B
FMU4x
Advantages
• Non-contact and unaffected by head pressures • Universally useable due to flexible measuring range • Also with ball valve •Remote access via Bluetooth® • Heartbeat Technology 2-wire (HART®, PA, FF), 4-wire HART® ±2mm/±0.08" –196 to +450°C/–321 to +842°F –1 to +160bar/–14.5 to +2,320psi Threads, flanges (DIN, ANSI, JIS), hygienic connections 70m/229ft
•High resistance • Self-cleaning effect of sensors • Integrated alarm/point level relay • Unaffected by stilling well material
Technical data • Connection •Accuracy • Process temperature • Process pressure • Process connection
2-/4-wire (HART®, DP) ±2mm/±0.08", +0.2% of the distance –40 to +105°C/–40 to +221°F +0.7 to +4bar/+10 to +58psi Threads, Tri-Clamp, flanges (DIN, ANSI, JIS) 25m/82ft
•Maximum
measuring range
Application limits
• Large changes in the stilling well cross section • Arrangement, size of equalizing openings • Plastic stilling wells
guided radar, capacitance guided radar, capacitance ultrasonics, guided radar float FMR54
•Vapor pressure radar
• DC starting at 1.4 • Stilling well > 12 m
Please note: Radar continued on Page 34
Please note: Ultrasonics continued on Page 74