Level measurement
74
Continuous level measurement in liquids
4. Instrument selection within the measuring principle
Ultrasonics
Required application data • Pressure and temperature • Vapor pressure of the medium (at 20°C/68°F)
Application limits for ultrasonic level measurement in liquids
• • • • • • • Strong temperature fluctuations in the measuring range can affect the accuracy
• Required material compatibility • Nozzle diameter/nozzle height
• Measuring range • Required accuracy • For bypass/stilling well: Internal pipe diameter
Damping caused by process
Surface of liquid
Filling curtain in the detection range
medium
surface
Calm 0dB
None
0dB
Up to 20°C/68°F 0dB
C
Waves
5 to 10dB
Small quantities
5 to 10 dB (FDU9x = 5 dB) 10 to 40 dB (FDU9x = 5 to 20 dB)
Up to 40°C/104°F
5 to 10dB
Strong turbulence
10 to 20dB
Large quantities
Up to 80°C/176°F
10 to 20dB
Foam Ask Endress+Hauser — — For applications, the sum of dampings (dB) and thus the range (m/ft) can be determined in the diagram from the table. — —
Range calculation and sensor selection Prosonic S FDU9x
R[m/ft]
Example (for FDU92): • Very turbulent surface: • Small quantities of filling curtain in the detection range:
25/82
20dB
FDU93
20/65
5dB
FDU92
• Total:
35dB range approx. 15m/49ft from diagram
10/32
FDU91 (F)
3/9.8
FDU90
0
0
20
40
60
80 A[dB]
Made with FlippingBook Digital Proposal Maker